Updating instructions
include::./_macros.adoc[]
Upgrading {ta} requires the following steps:
. Download the new RPM . Install the new RPM . Edit the configuration files to bring them up to date . Restart {ta} services
The most up to date RPMs are: link:{ta-dir}{ta-file}[]
[subs="attributes+"]
download
wget {ta-dir}{ta-file}
update
yum -y install {ta-file}
To update the config files, if necessary, look at the <<config>>
chapter for the full description of the available parameters and sections. This is particularly important if the first or second number in the version is different than the installed version.
To restart the services, do:
systemctl restart tiaudit-logger
systemctl restart tiaudit
== Re-loading the logs
If your version of {tc} is very old, you might consider re-loading the logs from scratch to make sure all {ta} features work properly.
Assuming that:
. Your database name is tiAudit
. The log files are in directory /var/log/ticrypt
to reload the data from scratch do:
Stop the services
systemctrl stop tiaudit systemctrl stop tiaudit-logger
Delete the database
clickhouse-client :) drop database tiAudit
Load the data
tiaudit-log-uploader -c /etc/tiaudit/log-uploader.toml /var/log/ticrypt
Re-start the services
systemctrl start tiaudit